Assessment Year 1994
Principal Product Wire garment hangers
NAICS
n/a
SIC 3496: Miscellaneous Fabricated Wire Products
Sales Range $5
M
to 10
M
# of Employees 100
Plant Area 105,000
ft2
Annual Production 200,000,000
lb
Production Hrs. Annual 5,670
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $195,979 4,638,922
kWh
Natural Gas $18,112 5,108
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $20,282 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,282

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $17,000 $27,760 $26,200
645,076
kWh
$(-9,200.0)
-
MMBtu
02 2.1133: Adjust burners for efficient operation $1,890 $540 - $1,890
-
MMBtu
03 2.7145: Install skylights $955 $1,300 $955
41,911
kWh
-
04 2.6218: Turn off equipment when not in use $437 $280 $437
-
kWh
-
TOTAL RECOMMENDED $20,282 $29,880 $27,592
686,987
kWh
$(-7,310.0)
-
MMBtu
TOTAL IMPLEMENTED $3,282 $2,120 $1,392
41,911
kWh
$1,890
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs