| Assessment Year | 1994 |
|---|---|
| Principal Product | Room air conditioners, split system type air conditioners |
| NAICS |
n/a
|
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 410 |
| Plant Area |
324,000
ft2
|
| Annual Production | 83,319
pieces
|
| Production Hrs. Annual | 1,912
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $473,491 | 8,199,883 |
kWh
|
$0.058 |
| Natural Gas | $152,756 | 48,229 |
MMBtu
|
$3.17 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $49,820 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,105 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7124: Make a practice of turning off lights when not needed | $34,315 | - |
$34,315
1,157,093
kWh
|
|
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $14,650 | - |
$14,650
-
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $455 | $370 |
$455
7,620
kWh
|
|
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $400 | - |
$400
13,482
kWh
|
|
| TOTAL RECOMMENDED | $49,820 | $370 |
$49,820
1,178,195
kWh
|
||
| TOTAL IMPLEMENTED | $15,105 | $370 |
$15,105
7,620
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs