| Assessment Year | 1994 |
|---|---|
| Principal Product | Printed heavy-duty plastic film shipping sacks |
| NAICS |
n/a
|
| SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 32,000,000
lb
|
| Production Hrs. Annual | 8,688
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $909,834 | 20,723,330 |
kWh
|
$0.044 |
| Natural Gas | $121,529 | 37,389 |
MMBtu
|
$3.25 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $77,432 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $47,882 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $33,400 | - |
$33,400
726,846
kWh
|
|
| 02 | 2.3511: Use plant owned transformers or lease transformers | $14,100 | $19,783 |
$14,100
(-145,076)
kWh
|
|
| 03 | 2.2691: Shut off cooling if cold outside air will cool process | $22,270 | $51,520 |
$22,270
614,302
kWh
|
|
| 04 | 2.2511: Insulate bare equipment | $7,280 | $500 |
$7,280
280,188
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $382 | $349 |
$382
10,551
kWh
|
|
| TOTAL RECOMMENDED | $77,432 | $72,152 |
$77,432
1,486,811
kWh
|
||
| TOTAL IMPLEMENTED | $47,882 | $20,132 |
$47,882
592,321
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs