Assessment Year | 1993 |
---|---|
Principal Product | paint |
NAICS |
n/a
|
SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 4,154
Tgal
|
Production Hrs. Annual | 3,240
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $109,653 | 1,232,708 |
kWh
|
$0.089 |
Natural Gas | $4,125 | 847 |
MMBtu
|
$4.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,615 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $620 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $23,650 | $25,500 |
$23,650
-
kWh
|
|
02 | 2.4314: Use synthetic lubricant | $710 | - |
$710
7,034
kWh
|
|
03 | 2.4131: Size electric motors for peak operating efficiency | $635 | $420 |
$635
10,258
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $620 | $400 |
$620
10,258
kWh
|
|
TOTAL RECOMMENDED | $25,615 | $26,320 |
$25,615
27,550
kWh
|
||
TOTAL IMPLEMENTED | $620 | $400 |
$620
10,258
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs