| Assessment Year | 1993 |
|---|---|
| Principal Product | natural gas compressors, oil field machinery, electric & pne |
| NAICS |
n/a
|
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
59,500
ft2
|
| Annual Production | 24
pieces
|
| Production Hrs. Annual | 2,586
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $90,557 | 1,136,284 |
kWh
|
$0.080 |
| Natural Gas | $7,543 | 1,507 |
MMBtu
|
$5.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,415 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,995 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7145: Install skylights | $3,620 | $3,430 |
$3,620
70,926
kWh
|
- | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $1,375 | $1,200 |
$1,375
16,999
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,180 | $540 |
$1,180
23,154
kWh
|
- | |
| 04 | 2.8121: Apply for tax-free status for energy purchases | $575 | $1,000 |
$575
-
kWh
|
- | |
| 05 | 2.8123: Pay utility bills on time | $440 | - | - | $440 | |
| 06 | 2.4131: Size electric motors for peak operating efficiency | $225 | - |
$225
4,982
kWh
|
- | |
| TOTAL RECOMMENDED | $7,415 | $6,170 |
$6,975
116,061
kWh
|
$440 | ||
| TOTAL IMPLEMENTED | $2,995 | $1,740 |
$2,555
40,153
kWh
|
$440 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs