| Assessment Year | 1993 |
|---|---|
| Principal Product | ready mix concrete |
| NAICS |
n/a
|
| SIC | 3273: Ready-Mixed Concrete |
| Sales Range | $5 M to 10M |
| # of Employees | 22 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 3,672
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $60,295 | 596,131 |
kWh
|
$0.10 |
| Other Energy | $99,000 | 12,600 |
MMBtu
|
$7.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,900 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,090 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $4,350 | $10,500 |
$4,350
-
kWh
|
|
| 02 | 2.7124: Make a practice of turning off lights when not needed | $1,750 | - |
$1,750
22,274
kWh
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,680 | $250 |
$1,680
25,498
kWh
|
|
| 04 | 2.6218: Turn off equipment when not in use | $1,660 | - |
$1,660
25,205
kWh
|
|
| 05 | 2.7141: Lower light fixtures in high ceiling areas | $1,160 | $320 |
$1,160
14,361
kWh
|
|
| 06 | 2.4314: Use synthetic lubricant | $300 | - |
$300
2,638
kWh
|
|
| TOTAL RECOMMENDED | $10,900 | $11,070 |
$10,900
89,976
kWh
|
||
| TOTAL IMPLEMENTED | $5,090 | $250 |
$5,090
72,977
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs