| Assessment Year | 1993 |
|---|---|
| Principal Product | repair and manufacture of prefabrica |
| NAICS |
n/a
|
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 267 |
| Plant Area |
957,000
ft2
|
| Annual Production | 450
pieces
|
| Production Hrs. Annual | 4,032
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $365,675 | 5,372,509 |
kWh
|
$0.068 |
| Natural Gas | $63,682 | 20,980 |
MMBtu
|
$3.04 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,561 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $13,967 | $31,500 |
$13,967
-
kWh
|
- | |
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,850 | - |
$2,850
72,978
kWh
|
- | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $2,740 | $608 |
$2,740
63,306
kWh
|
- | |
| 04 | 2.2136: Install / repair insulation on steam lines | $1,314 | $2,511 | - |
$1,314
-
MMBtu
|
|
| 05 | 2.4314: Use synthetic lubricant | $690 | - |
$690
9,086
kWh
|
- | |
| TOTAL RECOMMENDED | $21,561 | $34,619 |
$20,247
145,370
kWh
|
$1,314
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs