Assessment Year | 1993 |
---|---|
Principal Product | Pre-fabricated steel buildings, stee |
NAICS |
n/a
|
SIC | 3448: Prefabricated Metal Buildings and Components |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 48,000
ton
|
Production Hrs. Annual | 5,855
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $296,499 | 4,128,371 |
kWh
|
$0.072 |
Natural Gas | $25,756 | 5,544 |
MMBtu
|
$4.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $73,560 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $53,980 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $34,850 | $45,000 |
$34,850
-
kWh
|
- | |
02 | 2.7231: Use radiant heater for spot heating | $14,970 | $10,890 | - |
$14,970
-
MMBtu
|
|
03 | 2.8114: Change rate schedules or other changes in utility service | $10,850 | - |
$10,850
-
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,280 | $500 |
$8,280
186,108
kWh
|
- | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,640 | - |
$2,640
60,961
kWh
|
- | |
06 | 2.7124: Make a practice of turning off lights when not needed | $1,210 | $1,230 |
$1,210
19,637
kWh
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $760 | $3,920 |
$760
10,551
kWh
|
- | |
TOTAL RECOMMENDED | $73,560 | $61,540 |
$58,590
277,257
kWh
|
$14,970
-
MMBtu
|
||
TOTAL IMPLEMENTED | $53,980 | $45,500 |
$53,980
186,108
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |