Assessment Year | 1992 |
---|---|
Principal Product | TEFLON INJECTION MOLDING |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
n/a
|
Annual Production | 575,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $128,175 | 2,459,848 |
kWh
|
$0.052 |
Natural Gas | $1,316 | 274 |
MMBtu
|
$4.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,245 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,523 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $2,580 | $4,050 |
$2,580
101,114
kWh
|
- | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,142 | $80 |
$1,142
46,893
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $544 | - |
$688
26,964
kWh
|
$(-144.0) | |
04 | 2.4133: Use most efficient type of electric motors | $979 | $440 |
$979
19,637
kWh
|
- | |
TOTAL RECOMMENDED | $5,245 | $4,570 |
$5,389
194,608
kWh
|
$(-144.0) | ||
TOTAL IMPLEMENTED | $1,523 | $440 |
$1,667
46,601
kWh
|
$(-144.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs