Assessment Year | 1991 |
---|---|
Principal Product | STEEL REINFORCING BARS |
NAICS |
n/a
|
SIC | 3449: Miscellaneous Structural Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 40,000
ton
|
Production Hrs. Annual | 3,500
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $52,725 | 803,341 |
kWh
|
$0.066 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,459 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3134: Shift from daytime to nighttime operation | $4,016 | - |
$4,016
-
kWh
|
|
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $945 | $5,640 |
$945
16,413
kWh
|
|
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $330 | $340 |
$330
5,862
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $93 | $100 |
$93
1,172
kWh
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $75 | $5,858 |
$75
1,172
kWh
|
|
TOTAL RECOMMENDED | $5,459 | $11,938 |
$5,459
24,619
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs