Assessment Year | 1991 |
---|---|
Principal Product | STEEL FORGING |
NAICS |
n/a
|
SIC | 3462: Iron and Steel Forgings |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 12,000
ton
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $88,379 | 1,112,837 |
kWh
|
$0.079 |
Natural Gas | $258,797 | 107,778 |
MMBtu
|
$2.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $119,100 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2422: Use waste heat from hot flue gases to generate steam | $114,570 | $157,300 |
$(-13,090.0)
(-184,642)
kWh
|
$127,660
-
MMBtu
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $817 | $1,117 |
$817
14,068
kWh
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $2,180 | $660 |
$2,180
29,308
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,055 | - |
$1,210
17,585
kWh
|
- | $(-155.0) | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $450 | $1,005 |
$450
7,620
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $28 | $12 |
$28
293
kWh
|
- | - | |
TOTAL RECOMMENDED | $119,100 | $160,094 |
$(-8,405.0)
(-115,768)
kWh
|
$127,660
-
MMBtu
|
$(-155.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs