| Assessment Year | 1991 |
|---|---|
| Principal Product | STEEL FORGING |
| NAICS |
n/a
|
| SIC | 3462: Iron and Steel Forgings |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
n/a
|
| Annual Production | 12,000
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $88,379 | 1,112,837 |
kWh
|
$0.079 |
| Natural Gas | $258,797 | 107,778 |
MMBtu
|
$2.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $119,100 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2422: Use waste heat from hot flue gases to generate steam | $114,570 | $157,300 |
$(-13,090.0)
(-184,642)
kWh
|
$127,660
-
MMBtu
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $817 | $1,117 |
$817
14,068
kWh
|
- | - | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $2,180 | $660 |
$2,180
29,308
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,055 | - |
$1,210
17,585
kWh
|
- | $(-155.0) | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $450 | $1,005 |
$450
7,620
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $28 | $12 |
$28
293
kWh
|
- | - | |
| TOTAL RECOMMENDED | $119,100 | $160,094 |
$(-8,405.0)
(-115,768)
kWh
|
$127,660
-
MMBtu
|
$(-155.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs