| Assessment Year | 1991 |
|---|---|
| Principal Product | MAGAZINES, BROCHURES |
| NAICS |
n/a
|
| SIC | 2741: Miscellaneous Publishing |
| Sales Range | $10 M to 50M |
| # of Employees | 162 |
| Plant Area |
n/a
|
| Annual Production | 5,200,000
lb
|
| Production Hrs. Annual | 7,272
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $170,063 | 3,000,586 |
kWh
|
$0.057 |
| Natural Gas | $19,168 | 3,809 |
MMBtu
|
$5.03 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,271 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,348 | - |
$2,028
42,790
kWh
|
- | $(-680.0) | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $3,600 | $7,000 |
$3,600
-
kWh
|
- | - | |
| 03 | 2.7492: Use proper thickness of insulation on building envelope | $2,020 | $3,220 |
$1,310
41,325
kWh
|
$710
-
MMBtu
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $923 | $40 |
$923
29,308
kWh
|
- | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $240 | - |
$240
7,620
kWh
|
- | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $140 | $213 |
$140
4,689
kWh
|
- | - | |
| TOTAL RECOMMENDED | $8,271 | $10,473 |
$8,241
125,732
kWh
|
$710
-
MMBtu
|
$(-680.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs