Assessment Year 1990
Principal Product TREATED LUMBER
NAICS
n/a
SIC 2491: Wood Preserving
Sales Range $10
M
to 50
M
# of Employees 95
Plant Area
n/a
Annual Production 1,800
thousand feet
Production Hrs. Annual 8,712
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $137,743 1,986,811
kWh
Natural Gas $3,575 968
MMBtu
Wood $42,720 489,856
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $36,953 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,173

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Wood Savings
01 2.4322: Use or replace with energy efficient substitutes $12,075 $50,000 $12,075
215,416
kWh
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,720 $1,100 $4,720
94,666
kWh
- -
03 2.2121: Increase amount of condensate returned $4,500 - - - $4,500
-
MMBtu
04 2.2511: Insulate bare equipment $4,080 $16,400 - - $4,080
-
MMBtu
05 2.2162: Reduce excess steam bleeding $3,575 $3,750 - $3,575
-
MMBtu
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,030 - $2,030
55,393
kWh
- -
07 2.3212: Optimize plant power factor $1,800 $3,500 $1,800
-
kWh
- -
08 2.2135: Repair and eliminate steam leaks $1,600 $2,400 - - $1,600
-
MMBtu
09 2.4312: Improve lubrication practices $1,600 - $1,600
32,239
kWh
- -
10 2.2136: Install / repair insulation on steam lines $602 $2,665 - - $602
-
MMBtu
11 2.7142: Utilize higher efficiency lamps and/or ballasts $155 $319 $155
2,052
kWh
- -
12 2.2511: Insulate bare equipment $216 $875 - - $216
-
MMBtu
TOTAL RECOMMENDED $36,953 $81,009 $22,380
399,766
kWh
$3,575
-
MMBtu
$10,998
-
MMBtu
TOTAL IMPLEMENTED $13,173 $27,259 $6,675
96,718
kWh
- $6,498
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Wood Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs