ITAC Assessment: AM0086
ITAC logo
ITAC Assessment: AM0086
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1990
Principal Product FOAMED PLASTIC, PADDING
NAICS
n/a
SIC 3086: Plastics Foam Products
Sales Range $10
M
to 50
M
# of Employees 93
Plant Area
n/a
Annual Production 123,750
thousand feet
Production Hrs. Annual 6,264
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $127,928 2,441,090
kWh
Natural Gas $73,039 16,008
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $25,421 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,291

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4322: Use or replace with energy efficient substitutes $10,920 $50,000 $10,920
245,018
kWh
-
02 2.7492: Use proper thickness of insulation on building envelope $5,910 $3,880 - $5,910
-
MMBtu
03 2.2135: Repair and eliminate steam leaks $2,700 $800 - $2,700
-
MMBtu
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,570 $1,000 $2,570
82,063
kWh
-
05 2.4312: Improve lubrication practices $1,530 $3,000 $1,530
49,531
kWh
-
06 2.1233: Analyze flue gas for proper air/fuel ratio $1,130 $270 - $1,130
-
MMBtu
07 2.7142: Utilize higher efficiency lamps and/or ballasts $176 $257 $176
4,982
kWh
-
08 2.7121: Utilize daylight whenever possible in lieu of artificial light $318 - $318
10,258
kWh
-
09 2.2136: Install / repair insulation on steam lines $167 $275 - $167
-
MMBtu
TOTAL RECOMMENDED $25,421 $59,482 $15,514
391,852
kWh
$9,907
-
MMBtu
TOTAL IMPLEMENTED $24,291 $59,212 $15,514
391,852
kWh
$8,777
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs