| Assessment Year | 1990 |
|---|---|
| Principal Product | AGRICULTURE MACHINERY |
| NAICS |
n/a
|
| SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
| Sales Range | $10 M to 50M |
| # of Employees | 170 |
| Plant Area |
n/a
|
| Annual Production | 22,690
pieces
|
| Production Hrs. Annual | 2,265
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $91,147 | 1,089,390 |
kWh
|
$0.084 |
| Natural Gas | $617 | 69 |
MMBtu
|
$8.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,946 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,123 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,500 | $9,570 |
$3,110
41,911
kWh
|
$390 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,530 | $7,140 |
$1,530
48,066
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,330 | $960 |
$1,330
26,671
kWh
|
- | |
| 04 | 2.8114: Change rate schedules or other changes in utility service | $660 | - |
$660
-
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $86 | $74 |
$86
1,172
kWh
|
- | |
| 06 | 2.6212: Turn off equipment during breaks, reduce operating time | $423 | - |
$423
8,499
kWh
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $407 | $480 |
$407
8,206
kWh
|
- | |
| 08 | 2.6212: Turn off equipment during breaks, reduce operating time | $400 | - |
$400
7,913
kWh
|
- | |
| 09 | 2.6212: Turn off equipment during breaks, reduce operating time | $240 | - |
$240
4,689
kWh
|
- | |
| 10 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $210 | $200 |
$210
4,103
kWh
|
- | |
| 11 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $160 | - |
$160
3,224
kWh
|
- | |
| TOTAL RECOMMENDED | $8,946 | $18,424 |
$8,556
154,454
kWh
|
$390 | ||
| TOTAL IMPLEMENTED | $8,123 | $18,424 |
$7,733
138,042
kWh
|
$390 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs