Assessment Year 1989
Principal Product PLASTIC LINED PIPES
NAICS
n/a
SIC 3494: Valves and Pipe Fittings, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 115
Plant Area
n/a
Annual Production 144
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $261,894 4,370,457
kWh
Natural Gas $16,368 3,426
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $29,646 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $28,186

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.3191: Use demand controller or load shedder $8,120 $25,000 $8,120
-
kWh
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,348 $205 $4,554
109,906
kWh
- $(-206.0)
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,709 $1,500 $4,709
177,022
kWh
- -
04 2.7245: Use direct air supply to exhaust hoods $4,550 $8,250 - $4,550
-
MMBtu
-
05 2.2511: Insulate bare equipment $2,285 $3,250 $2,285
85,287
kWh
- -
06 2.2511: Insulate bare equipment $1,460 $1,050 - $1,460
-
MMBtu
-
07 2.2437: Recover waste heat from equipment $1,380 $700 - $1,380
-
MMBtu
-
08 2.3132: Recharge batteries on during off-peak demand periods $1,265 - $1,265
-
kWh
- -
09 2.8121: Apply for tax-free status for energy purchases $1,213 $2,500 - $1,213
-
MMBtu
-
10 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses $86 $81 $86
1,172
kWh
- -
11 2.4221: Install compressor air intakes in coolest locations $230 $410 $230
8,792
kWh
- -
TOTAL RECOMMENDED $29,646 $42,946 $21,249
382,179
kWh
$8,603
-
MMBtu
$(-206.0)
TOTAL IMPLEMENTED $28,186 $41,896 $21,249
382,179
kWh
$7,143
-
MMBtu
$(-206.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs