Assessment Year | 1989 |
---|---|
Principal Product | PLASTIC LINED PIPES |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
n/a
|
Annual Production | 144
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $261,894 | 4,370,457 |
kWh
|
$0.060 |
Natural Gas | $16,368 | 3,426 |
MMBtu
|
$4.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,646 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,186 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $8,120 | $25,000 |
$8,120
-
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,348 | $205 |
$4,554
109,906
kWh
|
- | $(-206.0) | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,709 | $1,500 |
$4,709
177,022
kWh
|
- | - | |
04 | 2.7245: Use direct air supply to exhaust hoods | $4,550 | $8,250 | - |
$4,550
-
MMBtu
|
- | |
05 | 2.2511: Insulate bare equipment | $2,285 | $3,250 |
$2,285
85,287
kWh
|
- | - | |
06 | 2.2511: Insulate bare equipment | $1,460 | $1,050 | - |
$1,460
-
MMBtu
|
- | |
07 | 2.2437: Recover waste heat from equipment | $1,380 | $700 | - |
$1,380
-
MMBtu
|
- | |
08 | 2.3132: Recharge batteries on during off-peak demand periods | $1,265 | - |
$1,265
-
kWh
|
- | - | |
09 | 2.8121: Apply for tax-free status for energy purchases | $1,213 | $2,500 | - |
$1,213
-
MMBtu
|
- | |
10 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $86 | $81 |
$86
1,172
kWh
|
- | - | |
11 | 2.4221: Install compressor air intakes in coolest locations | $230 | $410 |
$230
8,792
kWh
|
- | - | |
TOTAL RECOMMENDED | $29,646 | $42,946 |
$21,249
382,179
kWh
|
$8,603
-
MMBtu
|
$(-206.0) | ||
TOTAL IMPLEMENTED | $28,186 | $41,896 |
$21,249
382,179
kWh
|
$7,143
-
MMBtu
|
$(-206.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs