Assessment Year | 1988 |
---|---|
Principal Product | POTATO & CORN CHIPS |
NAICS |
n/a
|
SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
Sales Range | $10 M to 50M |
# of Employees | 233 |
Plant Area |
n/a
|
Annual Production | 31,000,000
lb
|
Production Hrs. Annual | 6,072
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $293,578 | 6,441,677 |
kWh
|
$0.046 |
Natural Gas | $451,743 | 125,178 |
MMBtu
|
$3.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,543 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,593 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2444: Use hot process fluids to preheat incoming process fluids | $30,343 | $60,000 |
$(-8,506.0)
(-138,042)
kWh
|
$38,849
-
MMBtu
|
|
02 | 2.2414: Use waste heat from hot flue gases to preheat | $14,450 | $10,000 | - |
$14,450
-
MMBtu
|
|
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $7,260 | $300 | - |
$7,260
-
MMBtu
|
|
04 | 2.7111: Reduce illumination to minimum necessary levels | $3,080 | $1,400 |
$3,080
50,703
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,030 | $303 |
$2,030
35,756
kWh
|
- | |
06 | 2.2135: Repair and eliminate steam leaks | $2,005 | $600 | - |
$2,005
-
MMBtu
|
|
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,490 | $1,100 |
$1,490
31,067
kWh
|
- | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $1,415 | - |
$1,415
19,343
kWh
|
- | |
09 | 2.2136: Install / repair insulation on steam lines | $470 | $300 | - |
$470
-
MMBtu
|
|
TOTAL RECOMMENDED | $62,543 | $74,003 |
$(-491.0)
(-1,173)
kWh
|
$63,034
-
MMBtu
|
||
TOTAL IMPLEMENTED | $45,593 | $63,400 |
$(-2,521.0)
(-36,929)
kWh
|
$48,114
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs