| Assessment Year | 1988 |
|---|---|
| Principal Product | STORAGE TANKS & VESSELS |
| NAICS |
n/a
|
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $50 M to 100M |
| # of Employees | 300 |
| Plant Area |
n/a
|
| Annual Production | 28,000
ton
|
| Production Hrs. Annual | 2,142
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $227,621 | 4,383,353 |
kWh
|
$0.052 |
| Natural Gas | $30,488 | 6,541 |
MMBtu
|
$4.66 |
| LPG | $10,000 | 470 |
MMBtu
|
$21.28 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,721 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,301 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $10,876 | - |
$10,876
-
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,301 | $1,500 |
$4,301
161,782
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $544 | $578 |
$544
9,086
kWh
|
|
| TOTAL RECOMMENDED | $15,721 | $2,078 |
$15,721
170,868
kWh
|
||
| TOTAL IMPLEMENTED | $4,301 | $1,500 |
$4,301
161,782
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs