| Assessment Year | 1988 |
|---|---|
| Principal Product | WELDED WIRE FABRIC |
| NAICS |
n/a
|
| SIC | 3315: Steel Wiredrawing and Steel Nails and Spikes |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
n/a
|
| Annual Production | 30,000
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $106,364 | 1,725,967 |
kWh
|
$0.062 |
| Natural Gas | $2,791 | 678 |
MMBtu
|
$4.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,135 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,345 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $5,350 | $10,500 |
$5,350
-
kWh
|
|
| 02 | 2.4312: Improve lubrication practices | $1,470 | - |
$1,470
35,170
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,085 | $2,300 |
$1,085
18,171
kWh
|
|
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $970 | $600 |
$970
23,154
kWh
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $260 | - |
$260
6,155
kWh
|
|
| TOTAL RECOMMENDED | $9,135 | $13,400 |
$9,135
82,650
kWh
|
||
| TOTAL IMPLEMENTED | $1,345 | $2,300 |
$1,345
24,326
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs