Assessment Year | 1988 |
---|---|
Principal Product | CHEMICAL FORMULATIONS |
NAICS |
n/a
|
SIC | 2891: Adhesives and Sealants |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
n/a
|
Annual Production | 202,400
pieces
|
Production Hrs. Annual | 2,777
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,961 | 412,954 |
kWh
|
$0.075 |
Natural Gas | $5,101 | 1,310 |
MMBtu
|
$3.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,733 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,156 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,523 | $2,737 |
$1,219
18,464
kWh
|
- | $304 | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $372 | $500 | - |
$522
-
MMBtu
|
$(-150.0) | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $309 | - |
$309
6,448
kWh
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $276 | $250 | - |
$276
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $54 | $47 |
$54
879
kWh
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $123 | $225 |
$61
1,172
kWh
|
$62
-
MMBtu
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $76 | $200 |
$76
1,465
kWh
|
- | - | |
TOTAL RECOMMENDED | $2,733 | $3,959 |
$1,719
28,428
kWh
|
$860
-
MMBtu
|
$154 | ||
TOTAL IMPLEMENTED | $1,156 | $1,175 |
$446
9,085
kWh
|
$860
-
MMBtu
|
$(-150.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs