| Assessment Year | 1988 |
|---|---|
| Principal Product | STEEL & ALUMINUM FASTENERS |
| NAICS |
n/a
|
| SIC | 3452: Bolts, Nuts, Screws, Rivets, and Washers |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
n/a
|
| Annual Production | 26,000,000
lb
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $482,750 | 11,427,022 |
kWh
|
$0.042 |
| Natural Gas | $332,272 | 99,740 |
MMBtu
|
$3.33 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,885 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $31,240 | $127,710 | - |
$31,240
-
MMBtu
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,300 | - |
$2,300
81,184
kWh
|
- | |
| 03 | 2.4312: Improve lubrication practices | $1,725 | - |
$1,725
60,961
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $390 | $235 |
$390
5,862
kWh
|
- | |
| 05 | 2.2511: Insulate bare equipment | $230 | $74 | - |
$230
-
MMBtu
|
|
| TOTAL RECOMMENDED | $35,885 | $128,019 |
$4,415
148,007
kWh
|
$31,470
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs