Assessment Year | 1988 |
---|---|
Principal Product | PLASTIC CONTAINERS |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 13,000,000
lb
|
Production Hrs. Annual | 8,472
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $528,507 | 9,645,076 |
kWh
|
$0.055 |
Natural Gas | $5,908 | 1,467 |
MMBtu
|
$4.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,432 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,564 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $7,062 | $5,600 |
$7,062
166,471
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,192 | $7,675 |
$6,192
120,750
kWh
|
|
03 | 2.2511: Insulate bare equipment | $2,294 | $1,450 |
$2,294
53,927
kWh
|
|
04 | 2.5122: Replace high resistance ducts, pipes, and fittings | $2,556 | $300 |
$2,556
60,082
kWh
|
|
05 | 2.4312: Improve lubrication practices | $1,619 | - |
$1,619
38,101
kWh
|
|
06 | 2.7111: Reduce illumination to minimum necessary levels | $652 | $500 |
$652
10,844
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $57 | $47 |
$57
879
kWh
|
|
TOTAL RECOMMENDED | $20,432 | $15,572 |
$20,432
451,054
kWh
|
||
TOTAL IMPLEMENTED | $12,564 | $7,850 |
$12,564
291,324
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs