| Assessment Year | 2023 |
|---|---|
| Principal Product | Plastics sheets |
| NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 40 |
| Plant Area |
95,000
ft2
|
| Annual Production | 33,000,000
lb
|
| Production Hrs. Annual | 4,800
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $270,847 | 6,469,383 |
kWh
|
$0.042 | |
| Electricity Demand | $148,704 | 18,588 |
kW-mo/yr
|
$8.00 | |
| Electricity Fees | $33,588 | - |
|
- | |
| Natural Gas | $167,837 | 25,240 |
MMBtu
|
$6.65 | |
| Waste Disposal Costs | |||||
| Water Usage | $3,244 | 1,291 |
Tgal
|
$2.51 | |
| Water Disposal | $4,754 | 1,291 |
Tgal
|
$3.68 | |
| TOTAL YEARLY COSTS | $628,974 | ||||
| RECOMMENDED SAVINGS* | $20,431 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $7,352 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2442: Preheat combustion air with waste heat | $8,579 | $10,000 | - | - |
$8,579
-
MMBtu
|
- | |
| 02 | 2.7231: Use radiant heater for spot heating | $4,500 | $12,375 | - | - |
$4,500
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,827 | $3,344 |
$1,915
45,590
kWh
|
$912
-
kW-mo/yr
|
- | - | |
| 04 | 2.7211: Clean and maintain refrigerant condensers and towers | $1,847 | $800 |
$1,452
34,567
kWh
|
$395
-
kW-mo/yr
|
- | - | |
| 05 | 3.4116: Meter recycled water (to reduce sewer charges) | $1,426 | $750 | - | - | - |
$1,426
-
Tgal
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,252 | $1,288 |
$848
20,201
kWh
|
$404
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $20,431 | $28,557 |
$4,215
100,358
kWh
|
$1,711
-
kW-mo/yr
|
$13,079
-
MMBtu
|
$1,426
-
Tgal
|
||
| TOTAL IMPLEMENTED | $7,352 | $6,182 |
$4,215
100,358
kWh
|
$1,711
-
kW-mo/yr
|
- |
$1,426
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs