Assessment Year 2012
Principal Product Glass Windows
NAICS 327211: Flat Glass Manufacturing
SIC 3211: Flat Glass
Sales Range $50
M
to 100
M
# of Employees 350
Plant Area 422,000
ft2
Annual Production 2,360,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $746,966 14,380,800
kWh
Electricity Demand $418,290 39,290
kW-mo/yr
Natural Gas $43,380 5,390
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $51,567 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,425

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
01 2.4313: Provide proper maintenance of motor driven equipment $3,505 - $2,729
52,575
kWh
$1,077
-
kW-mo/yr
$(-300.0)
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,425 $125 $2,456
47,317
kWh
$969
-
kW-mo/yr
-
03 2.7221: Lower temperature during the winter season and vice-versa $1,646 - $1,378
22,377
kWh
$267
-
kW-mo/yr
-
04 2.3131: Reschedule plant operations or reduce load to avoid peaks $7,789 $250 - $7,789
-
kW-mo/yr
-
05 2.7111: Reduce illumination to minimum necessary levels $1,041 $200 $594
9,646
kWh
$447
-
kW-mo/yr
-
06 2.7145: Install skylights $34,161 $123,125 $6,446
104,642
kWh
$1,715
-
kW-mo/yr
$26,000
TOTAL RECOMMENDED $51,567 $123,700 $13,603
236,557
kWh
$12,265
-
kW-mo/yr
$25,700
TOTAL IMPLEMENTED $3,425 $125 $2,456
47,317
kWh
$969
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs