| Assessment Year | 2002 |
|---|---|
| Principal Product | Currugated Boxes |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
200,000
ft2
|
| Annual Production | 1,100,000,000
thousand feet
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $133,466 | 4,859,250 |
kWh
|
$0.027 |
| Electricity Demand | $84,234 | 10,789 |
kW-mo/yr
|
$7.81 |
| Electricity Fees | $45,897 | - |
|
- |
| Natural Gas | $481,174 | 62,790 |
MMBtu
|
$7.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,415 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,430 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $24,059 | $25,000 | - | - |
$24,059
-
MMBtu
|
|
| 02 | 2.7135: Install occupancy sensors | $6,072 | $18,000 | n/a |
$3,867
134,280
kWh
|
$2,205
-
kW-mo/yr
|
- |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $4,938 | $11,250 | n/a | - | - |
$4,938
-
MMBtu
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,916 | $1,549 |
$1,260
43,765
kWh
|
$656
-
kW-mo/yr
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $741 | - |
$471
16,365
kWh
|
$270
-
kW-mo/yr
|
- | |
| 06 | 2.2136: Install / repair insulation on steam lines | $689 | $39 | - | - |
$689
-
MMBtu
|
|
| TOTAL RECOMMENDED | $38,415 | $55,838 |
$5,598
194,410
kWh
|
$3,131
-
kW-mo/yr
|
$29,686
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,430 | $39 |
$471
16,365
kWh
|
$270
-
kW-mo/yr
|
$689
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs