Assessment Year | 1993 |
---|---|
Principal Product | Lithographic printing |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 128 |
Plant Area |
n/a
|
Annual Production | 3,000,000
lb
|
Production Hrs. Annual | 6,750
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $124,981 | 1,542,497 |
kWh
|
$0.081 |
Natural Gas | $12,653 | 2,463 |
MMBtu
|
$5.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,906 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,075 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,600 | $5,042 |
$6,600
81,477
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $950 | $2,400 |
$950
11,723
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $478 | $525 |
$478
5,862
kWh
|
- | |
04 | 2.8113: Purchase gas directly from a contract gas supplier | $5,877 | $500 | - |
$5,877
-
MMBtu
|
|
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,427 | $10,000 |
$4,427
-
kWh
|
- | |
06 | 2.3132: Recharge batteries on during off-peak demand periods | $3,198 | - |
$3,198
-
kWh
|
- | |
07 | 2.7221: Lower temperature during the winter season and vice-versa | $269 | $400 | - |
$269
-
MMBtu
|
|
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $107 | - |
$107
1,465
kWh
|
- | |
TOTAL RECOMMENDED | $21,906 | $18,867 |
$15,760
100,527
kWh
|
$6,146
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,075 | $500 |
$3,198
-
kWh
|
$5,877
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs