| Assessment Year | 1988 |
|---|---|
| Principal Product | AIR-COOLED ENGINES |
| NAICS |
n/a
|
| SIC | 3519: Internal Combustion Engines, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
n/a
|
| Annual Production | 22,000
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $226,863 | 3,711,606 |
kWh
|
$0.061 |
| Natural Gas | $177,844 | 36,328 |
MMBtu
|
$4.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,795 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,795 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4312: Improve lubrication practices | $3,047 | - |
$3,047
49,824
kWh
|
- | - | |
| 02 | 2.3132: Recharge batteries on during off-peak demand periods | $5,565 | - |
$5,565
-
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,218 | $1,926 |
$2,218
26,377
kWh
|
- | - | |
| 04 | 2.7226: Use computer programs to optimize hvac performance | $1,933 | $5,000 |
$1,933
31,653
kWh
|
- | - | |
| 05 | 2.2437: Recover waste heat from equipment | $1,461 | $1,400 | - |
$1,461
-
MMBtu
|
- | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,571 | $500 | - |
$2,671
-
MMBtu
|
$(-100.0) | |
| TOTAL RECOMMENDED | $16,795 | $8,826 |
$12,763
107,854
kWh
|
$4,132
-
MMBtu
|
$(-100.0) | ||
| TOTAL IMPLEMENTED | $16,795 | $8,826 |
$12,763
107,854
kWh
|
$4,132
-
MMBtu
|
$(-100.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs