Assessment Year | 1987 |
---|---|
Principal Product | SHIPPING CONTAINERS |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 40,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $267,588 | 5,478,019 |
kWh
|
$0.049 |
Natural Gas | $298,890 | 65,415 |
MMBtu
|
$4.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,041 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,740 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4312: Improve lubrication practices | $2,205 | - |
$2,205
45,135
kWh
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,378 | - |
$1,378
28,136
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,998 | $1,385 |
$4,998
102,286
kWh
|
- | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $8,364 | $500 | - |
$8,614
-
MMBtu
|
$(-250.0) | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $9,096 | $32,000 | - |
$9,096
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $26,041 | $33,885 |
$8,581
175,557
kWh
|
$17,710
-
MMBtu
|
$(-250.0) | ||
TOTAL IMPLEMENTED | $14,740 | $1,885 |
$6,376
130,422
kWh
|
$8,614
-
MMBtu
|
$(-250.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs