Assessment Year | 2002 |
---|---|
Principal Product | Treadmills |
NAICS |
n/a
|
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | less than $500 k |
# of Employees | 1,500 |
Plant Area |
470,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 5,030
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $533,846 | 17,762,456 |
kWh
|
$0.030 |
Electricity Demand | $317,677 | 2,110 |
kW-mo/yr
|
$150.56 |
Electricity Fees | $51,091 | - |
|
- |
Natural Gas | $255,285 | 109,555 |
MMBtu
|
$2.33 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $113,595 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $86,926 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $4,413 | $8,128 |
$2,500
78,585
kWh
|
$1,913
-
kW-mo/yr
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $3,462 | $610 | - | - |
$3,462
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,467 | $460 |
$3,244
102,067
kWh
|
$3,223
-
kW-mo/yr
|
- | - | |
04 | 2.3212: Optimize plant power factor | $14,706 | $18,000 | - |
$14,706
-
kW-mo/yr
|
- | - | |
05 | 2.7243: Improve air circulation with destratification fans / other methods | $22,256 | $31,800 |
$520
16,337
kWh
|
$410
-
kW-mo/yr
|
$21,326
-
MMBtu
|
- | |
06 | 3.5311: Recover and reuse waste material | $62,291 | $17,100 | - | - | - |
$62,291
-
lb
|
|
TOTAL RECOMMENDED | $113,595 | $76,098 |
$6,264
196,989
kWh
|
$20,252
-
kW-mo/yr
|
$24,788
-
MMBtu
|
$62,291
-
lb
|
||
TOTAL IMPLEMENTED | $86,926 | $36,170 |
$3,244
102,067
kWh
|
$17,929
-
kW-mo/yr
|
$3,462
-
MMBtu
|
$62,291
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs