Assessment Year | 2013 |
---|---|
Principal Product | Vehicle testing |
NAICS | 541330: Engineering Services |
SIC | 8711: Engineering Services |
Sales Range | $1 M to 5M |
# of Employees | 56 |
Plant Area |
60,000
ft2
|
Annual Production | 300
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $291,360 | 2,262,900 |
kWh
|
$0.13 |
Natural Gas | $14,569 | 1,754 |
MMBtu
|
$8.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $85,354 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,154 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4311: Recover mechanical energy | $45,000 | $8,000 |
$45,000
348,511
kWh
|
|
02 | 2.4311: Recover mechanical energy | $18,100 | $15,500 |
$18,100
140,287
kWh
|
|
03 | 2.4323: Use optimum size and capacity equipment | $16,100 | $5,500 |
$16,100
125,160
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,154 | $29,153 |
$6,154
47,781
kWh
|
|
TOTAL RECOMMENDED | $85,354 | $58,153 |
$85,354
661,739
kWh
|
||
TOTAL IMPLEMENTED | $6,154 | $29,153 |
$6,154
47,781
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs