| Assessment Year | 2011 |
|---|---|
| Principal Product | Aluminum slugs |
| NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
| SIC | 3466: Crowns and Closures |
| Sales Range | less than $500 k |
| # of Employees | 90 |
| Plant Area |
72,000
ft2
|
| Annual Production | 86,000,000
lb
|
| Production Hrs. Annual | 7,824
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $332,865 | 5,839,740 |
kWh
|
$0.057 |
| Natural Gas | $1,264,839 | 195,593 |
MMBtu
|
$6.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $76,519 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,244 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Natural Gas Savings | Other Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1116: Improve combustion control capability | $38,198 | $7,100 |
$38,198
-
MMBtu
|
- | |
| 02 | 2.1116: Improve combustion control capability | $3,190 | $2,000 |
$3,190
-
MMBtu
|
- | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $30,887 | $50,000 | - |
$30,887
-
MMBtu
|
|
| 04 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $4,244 | $1,000 |
$4,244
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $76,519 | $60,100 |
$45,632
-
MMBtu
|
$30,887
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,244 | $1,000 |
$4,244
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs