Assessment Year | 1999 |
---|---|
Principal Product | Metal Fittings |
NAICS |
n/a
|
SIC | 3451: Screw Machine Products |
Sales Range | $5 M to 10M |
# of Employees | 48 |
Plant Area |
25,000
ft2
|
Annual Production | 114,000,000
pieces
|
Production Hrs. Annual | 5,330
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $28,155 | 732,122 |
kWh
|
$0.038 |
Electricity Demand | $30,278 | 2,652 |
kW-mo/yr
|
$11.42 |
Electricity Fees | $3,582 | - |
|
- |
Natural Gas | $3,494 | 661 |
MMBtu
|
$5.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $369,162 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,137 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,826 | $2,464 |
$1,191
33,998
kWh
|
$878
-
kW-mo/yr
|
- | - | - | $70 | - | $687 | |
02 | 2.2437: Recover waste heat from equipment | $1,069 | $500 | - | - | - |
$1,069
-
MMBtu
|
- | - | - | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $10,056 | $40,000 | - | - | $10,056 | - | - | - | - | - | |
04 | 3.4112: Recovery metals from rinse water(evap., ion exchange, ro, electrolysis, electrodialysis) and reuse rinse water | $12,311 | $40,000 | - | - | - | - |
$7,700
-
gal
|
- | $(-1,429.0) | $6,040 | |
05 | 4.511: Expand operations into unused space | $342,900 | $683,000 | - | - | - | - | - | - | $342,900 | - | |
TOTAL RECOMMENDED | $369,162 | $765,964 |
$1,191
33,998
kWh
|
$878
-
kW-mo/yr
|
$10,056 |
$1,069
-
MMBtu
|
$7,700
-
gal
|
$70 | $341,471 | $6,727 | ||
TOTAL IMPLEMENTED | $15,137 | $42,464 |
$1,191
33,998
kWh
|
$878
-
kW-mo/yr
|
- | - |
$7,700
-
gal
|
$70 | $(-1,429.0) | $6,727 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs