Assessment Year | 1995 |
---|---|
Principal Product | Metal heat Treating |
NAICS |
n/a
|
SIC | 3398: Metal Heat Treating |
Sales Range | $5 M to 10M |
# of Employees | 52 |
Plant Area |
110,000
ft2
|
Annual Production | 60,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $179,718 | 3,936,401 |
kWh
|
$0.046 |
Natural Gas | $294,237 | 132,939 |
MMBtu
|
$2.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,803 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,803 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,181 | $1,433 |
$2,181
47,479
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,738 | $25,330 |
$2,738
59,496
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $139 | $350 |
$139
2,931
kWh
|
- | |
04 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $4,745 | $4,000 | - |
$4,745
-
MMBtu
|
|
TOTAL RECOMMENDED | $9,803 | $31,113 |
$5,058
109,906
kWh
|
$4,745
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,803 | $31,113 |
$5,058
109,906
kWh
|
$4,745
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs