Assessment Year | 2024 |
---|---|
Principal Product | Canned Foods |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2032: Canned Specialties |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
267,000
ft2
|
Annual Production | 33,000,000
pieces
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $206,739 | 6,394,920 |
kWh
|
$0.032 | |
Electricity Demand | $348,620 | 15,845 |
kW-mo/yr
|
$22.00 | |
Electricity Fees | $39,864 | - |
|
- | |
Natural Gas | $301,553 | 66,552 |
MMBtu
|
$4.53 | |
Waste Disposal Costs | |||||
Water Usage | $271,417 | 56,678 |
Tgal
|
$4.79 | |
TOTAL YEARLY COSTS | $1,168,193 | ||||
RECOMMENDED SAVINGS* | $189,720 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $21,720 | $14,950 | - | - | $21,720 | - | |
02 | 2.3212: Optimize plant power factor | $7,741 | $12,220 | - | - | $7,741 | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,721 | $15,563 |
$6,783
209,994
kWh
|
$10,938
-
kW-mo/yr
|
- | - | |
04 | 2.7135: Install occupancy sensors | $112 | $406 |
$112
3,469
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $20,826 | $10,980 |
$20,826
650,799
kWh
|
- | - | - | |
06 | 2.4235: Remove or close off unneeded compressed air lines | $4,470 | $1,120 |
$2,299
71,855
kWh
|
$2,171
-
kW-mo/yr
|
- | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,544 | $12,225 |
$3,544
110,761
kWh
|
- | - | - | |
08 | 2.9114: Use solar heat to make electricty | $78,236 | $775,946 |
$33,945
1,060,797
kWh
|
$44,291
-
kW-mo/yr
|
- | - | |
09 | 2.2692: Use outside cold water source as a supply of cooling water | $35,350 | $159,350 |
$638
19,748
kWh
|
$23,636
-
kW-mo/yr
|
- |
$11,076
-
Tgal
|
|
TOTAL RECOMMENDED | $189,720 | $1,002,760 |
$68,147
2,127,423
kWh
|
$81,036
-
kW-mo/yr
|
$29,461 |
$11,076
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs