| Assessment Year | 1994 |
|---|---|
| Principal Product | Injection molded platics |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 1,047 |
| Plant Area |
450,000
ft2
|
| Annual Production | 80,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $369,136 | 10,405,334 |
kWh
|
$0.035 |
| Natural Gas | $89,509 | 25,961 |
MMBtu
|
$3.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,136 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $7,563 | $15,800 | n/a |
$7,563
175,850
kWh
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,502 | $2,161 | n/a |
$1,502
34,877
kWh
|
| 03 | 2.2511: Insulate bare equipment | $1,017 | $205 | n/a |
$1,017
23,740
kWh
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,054 | $10,016 | n/a |
$5,054
142,438
kWh
|
| TOTAL RECOMMENDED | $15,136 | $28,182 |
$15,136
376,905
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs