Assessment Year | 2022 |
---|---|
Principal Product | Lithium-ion Batteries |
NAICS | 335911: Storage Battery Manufacturing |
SIC | 3691: Storage Batteries |
Sales Range | $10 M to 50M |
# of Employees | 25 |
Plant Area |
240,000
ft2
|
Annual Production | 6,417
units
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $626,056 | 11,906,395 |
kWh
|
$0.053 | |
Electricity Demand | $213,430 | 32,449 |
kW-mo/yr
|
$6.58 | |
Electricity Fees | $127,411 | - |
|
- | |
Natural Gas | $238,445 | 30,910 |
MMBtu
|
$7.71 | |
Waste Disposal Costs | |||||
Water Usage | $18,519 | 4,720 |
Tgal
|
$3.92 | |
Water Disposal | $17,607 | 1,687 |
Tgal
|
$10.44 | |
TOTAL YEARLY COSTS | $1,241,468 | ||||
RECOMMENDED SAVINGS* | $766,653 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $586,028 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $320,724 | $1,068,750 |
$450,500
8,500,000
kWh
|
$78,924
-
kW-mo/yr
|
$(-123,700.0)
-
MMBtu
|
$(-85,000.0) | - | |
02 | 2.8113: Purchase gas directly from a contract gas supplier | $175,432 | - | - | - | - | $175,432 | - | |
03 | 2.3191: Use demand controller or load shedder | $59,112 | $64,054 |
$44,173
833,448
kWh
|
$14,939
-
kW-mo/yr
|
- | - | - | |
04 | 2.7141: Lower light fixtures in high ceiling areas | $5,193 | $12,000 |
$3,573
67,408
kWh
|
$1,620
-
kW-mo/yr
|
- | - | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $3,361 | - |
$3,361
63,410
kWh
|
- | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,831 | $290 |
$2,831
53,414
kWh
|
- | - | - | - | |
07 | 4.662: Level one – add communication using iiot devices to existing control system to modify operations | $200,000 | - | - | - | - | - | $200,000 | |
TOTAL RECOMMENDED | $766,653 | $1,145,094 |
$504,438
9,517,680
kWh
|
$95,483
-
kW-mo/yr
|
$(-123,700.0)
-
MMBtu
|
$90,432 | $200,000 | ||
TOTAL IMPLEMENTED | $586,028 | $1,133,094 |
$500,865
9,450,272
kWh
|
$93,863
-
kW-mo/yr
|
$(-123,700.0)
-
MMBtu
|
$(-85,000.0) | $200,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs