| Assessment Year | 2021 |
|---|---|
| Principal Product | Medical Furnishing |
| NAICS | 337127: Institutional Furniture Manufacturing |
| SIC | 2599: Furniture and Fixtures, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
80,000
ft2
|
| Annual Production | 31,890
units
|
| Production Hrs. Annual | 3,134
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $44,471 | 642,415 |
kWh
|
$0.069 |
| Electricity Demand | $26,652 | 3,796 |
kW-mo/yr
|
$7.02 |
| Electricity Fees | $11,639 | - |
|
- |
| Natural Gas | $18,767 | 3,439 |
MMBtu
|
$5.46 |
| TOTAL YEARLY COSTS | $101,529 | |||
| RECOMMENDED SAVINGS* | $78,204 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $36,128 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $42,076 | $359,360 |
$42,076
609,804
kWh
|
- | - | - | |
| 02 | 2.7425: Clean or color roof to reduce solar load | $19,566 | $32,210 |
$(-33.0)
(-483)
kWh
|
- | - | $19,599 | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,767 | $956 |
$3,767
54,601
kWh
|
- | - | - | |
| 04 | 2.5115: Reposition oven walls to reduce heated space | $3,003 | $750 | - | - |
$3,003
-
MMBtu
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $2,600 | $3,317 |
$1,476
21,395
kWh
|
$1,124
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,328 | $5,468 |
$956
13,852
kWh
|
$372
-
kW-mo/yr
|
- | - | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $602 | - |
$602
8,719
kWh
|
- | - | - | |
| 08 | 4.322: Eliminate old stock and modify inventory control | $5,262 | $7,180 |
$(-6.1)
(-89)
kWh
|
$(-192.1)
-
kW-mo/yr
|
- | $5,460 | |
| TOTAL RECOMMENDED | $78,204 | $409,241 |
$48,838
707,799
kWh
|
$1,304
-
kW-mo/yr
|
$3,003
-
MMBtu
|
$25,059 | ||
| TOTAL IMPLEMENTED | $36,128 | $49,881 |
$6,762
97,995
kWh
|
$1,304
-
kW-mo/yr
|
$3,003
-
MMBtu
|
$25,059 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs