| Assessment Year | 2020 |
|---|---|
| Principal Product | Reclaimed Water and Bio-Solids |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | $10 M to 50M |
| # of Employees | 24 |
| Plant Area |
767,250
ft2
|
| Annual Production | 7,439,700
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,063,061 | 16,988,917 |
kWh
|
$0.063 |
| TOTAL YEARLY COSTS | $1,063,061 | |||
| RECOMMENDED SAVINGS* | $128,672 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $128,672 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $67,090 | $20,230 |
$67,090
1,073,441
kWh
|
- | - | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $51,046 | $88,272 |
$51,046
816,732
kWh
|
- | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $10,536 | - |
$9,929
158,869
kWh
|
$359 | $248 | |
| TOTAL RECOMMENDED | $128,672 | $108,502 |
$128,065
2,049,042
kWh
|
$359 | $248 | ||
| TOTAL IMPLEMENTED | $128,672 | $108,502 |
$128,065
2,049,042
kWh
|
$359 | $248 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs