| Assessment Year | 1994 |
|---|---|
| Principal Product | Packaging Machinery |
| NAICS |
n/a
|
| SIC | 3565: Packaging Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 145 |
| Plant Area |
130,000
ft2
|
| Annual Production | 85
pieces
|
| Production Hrs. Annual | 4,121
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $150,360 | 2,006,448 |
kWh
|
$0.075 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $119,202 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $51,757 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,948 | $39,507 |
$32,948
445,193
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,388 | $1,750 |
$1,388
18,757
kWh
|
|
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $16,867 | $24,660 |
$16,867
228,019
kWh
|
|
| 04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $6,763 | $22,550 |
$6,763
91,442
kWh
|
|
| 05 | 2.7271: Replace electric reheat with heat pipes | $11,259 | $38,450 |
$11,259
152,110
kWh
|
|
| 06 | 2.3113: Make ice during off peak hours for cooling | $49,423 | $76,330 |
$49,423
-
kWh
|
|
| 07 | 2.4133: Use most efficient type of electric motors | $554 | $794 |
$554
7,620
kWh
|
|
| TOTAL RECOMMENDED | $119,202 | $204,041 |
$119,202
943,141
kWh
|
||
| TOTAL IMPLEMENTED | $51,757 | $66,711 |
$51,757
699,589
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs