| Assessment Year | 1994 |
|---|---|
| Principal Product | Frozen Seafood |
| NAICS |
n/a
|
| SIC | 2092: Prepared Fresh or Frozen Fish and Seafoods |
| Sales Range | $100 M to 500M |
| # of Employees | 500 |
| Plant Area |
150,000
ft2
|
| Annual Production | 120,000
lb
|
| Production Hrs. Annual | 3,800
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $632,054 | 9,672,040 |
kWh
|
$0.065 |
| Natural Gas | $42,894 | 7,661 |
MMBtu
|
$5.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $63,577 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $36,157 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3132: Recharge batteries on during off-peak demand periods | $3,450 | - |
$3,450
-
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $9,296 | $19,877 |
$9,296
144,197
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,852 | $951 |
$6,852
134,818
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,351 | $8,499 |
$2,351
42,204
kWh
|
- | |
| 05 | 2.7144: Install spectral reflectors / delamp | $8,930 | $9,403 |
$8,930
133,060
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $379 | $720 |
$379
6,155
kWh
|
- | |
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $5,278 | $4,190 |
$5,278
116,940
kWh
|
- | |
| 08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $738 | $1,000 | - |
$738
-
MMBtu
|
|
| 09 | 2.2447: Heat water with exhaust heat | $5,098 | $1,800 |
$5,098
79,132
kWh
|
- | |
| 10 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $21,205 | $75,000 |
$21,205
-
kWh
|
- | |
| TOTAL RECOMMENDED | $63,577 | $121,440 |
$62,839
656,506
kWh
|
$738
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $36,157 | $42,920 |
$36,157
571,219
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs