Assessment Year | 2011 |
---|---|
Principal Product | MRI Coils |
NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
SIC | 3826: Laboratory Analytical Instruments |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
72,000
ft2
|
Annual Production | 6,000
pieces
|
Production Hrs. Annual | 3,600
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $139,902 | 1,770,560 |
kWh
|
$0.079 |
Electricity Demand | $25,346 | 3,922 |
kW-mo/yr
|
$6.46 |
Natural Gas | $21,285 | 2,399 |
MMBtu
|
$8.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,109 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $1,586 | $1,463 |
$1,586
15,840
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,128 | $900 |
$1,016
12,887
kWh
|
$112
-
kW-mo/yr
|
- | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,056 | - |
$1,056
13,384
kWh
|
- | - | |
04 | 2.7135: Install occupancy sensors | $607 | $300 |
$447
5,661
kWh
|
- | $160 | |
05 | 2.6211: Conserve energy by efficient use of vending machines | $456 | $998 |
$456
5,779
kWh
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $276 | $25 |
$227
2,881
kWh
|
$49
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $5,109 | $3,686 |
$4,788
56,432
kWh
|
$161
-
kW-mo/yr
|
$160 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs