| Assessment Year | 1994 |
|---|---|
| Principal Product | motor vehicle body side molding |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
70,200
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $98,500 | 1,762,016 |
kWh
|
$0.056 |
| Natural Gas | $7,257 | 1,446 |
MMBtu
|
$5.02 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,772 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,772 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $262 | - |
$262
10,551
kWh
|
- | - | |
| 02 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $1,105 | $1,500 |
$1,105
44,256
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,283 | $1,845 |
$972
18,757
kWh
|
$(-200.0)
-
MMBtu
|
$511 | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,287 | $1,920 |
$1,321
29,601
kWh
|
$(-314.0)
-
MMBtu
|
$280 | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,835 | $10,000 |
$7,435
99,941
kWh
|
$(-1,600.0)
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $9,772 | $15,265 |
$11,095
203,106
kWh
|
$(-2,114.0)
-
MMBtu
|
$791 | ||
| TOTAL IMPLEMENTED | $9,772 | $15,265 |
$11,095
203,106
kWh
|
$(-2,114.0)
-
MMBtu
|
$791 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs