Assessment Year | 1994 |
---|---|
Principal Product | motor vehicle body side molding |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
70,200
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,500 | 1,762,016 |
kWh
|
$0.056 |
Natural Gas | $7,257 | 1,446 |
MMBtu
|
$5.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,772 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,772 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $262 | - |
$262
10,551
kWh
|
- | - | |
02 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $1,105 | $1,500 |
$1,105
44,256
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,283 | $1,845 |
$972
18,757
kWh
|
$(-200.0)
-
MMBtu
|
$511 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,287 | $1,920 |
$1,321
29,601
kWh
|
$(-314.0)
-
MMBtu
|
$280 | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,835 | $10,000 |
$7,435
99,941
kWh
|
$(-1,600.0)
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $9,772 | $15,265 |
$11,095
203,106
kWh
|
$(-2,114.0)
-
MMBtu
|
$791 | ||
TOTAL IMPLEMENTED | $9,772 | $15,265 |
$11,095
203,106
kWh
|
$(-2,114.0)
-
MMBtu
|
$791 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs