Assessment Year | 1993 |
---|---|
Principal Product | Turbine Parts |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
58,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $174,317 | 3,366,940 |
kWh
|
$0.052 |
Natural Gas | $6,701 | 1,283 |
MMBtu
|
$5.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,374 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,409 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $1,246 | - |
$1,246
-
kWh
|
|
02 | 2.3191: Use demand controller or load shedder | $2,409 | - |
$2,409
-
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,119 | $3,091 |
$1,119
-
kWh
|
|
04 | 2.7226: Use computer programs to optimize hvac performance | $9,600 | - |
$9,600
-
kWh
|
|
TOTAL RECOMMENDED | $14,374 | $3,091 |
$14,374
-
kWh
|
||
TOTAL IMPLEMENTED | $2,409 | - |
$2,409
-
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs