Assessment Year 1991
Principal Product FIBERGLASS PANEL
NAICS
n/a
SIC 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers
Sales Range $50
M
to 100
M
# of Employees 130
Plant Area
n/a
Annual Production 40,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $220,055 4,773,154
kWh
Natural Gas $361,083 144,998
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,623 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3212: Optimize plant power factor $3,936 $4,500 $3,936
-
kWh
-
02 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $4,115 - $4,115
127,491
kWh
-
03 2.7111: Reduce illumination to minimum necessary levels $931 - $931
19,637
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $885 - $885
11,723
kWh
-
05 2.1224: Replace boiler $13,756 - - $13,756
-
MMBtu
TOTAL RECOMMENDED $23,623 $4,500 $9,867
158,851
kWh
$13,756
-
MMBtu
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs