Assessment Year | 1991 |
---|---|
Principal Product | FIBERGLASS PANEL |
NAICS |
n/a
|
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $50 M to 100M |
# of Employees | 130 |
Plant Area |
n/a
|
Annual Production | 40,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $220,055 | 4,773,154 |
kWh
|
$0.046 |
Natural Gas | $361,083 | 144,998 |
MMBtu
|
$2.49 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,623 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $3,936 | $4,500 |
$3,936
-
kWh
|
- | |
02 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $4,115 | - |
$4,115
127,491
kWh
|
- | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $931 | - |
$931
19,637
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $885 | - |
$885
11,723
kWh
|
- | |
05 | 2.1224: Replace boiler | $13,756 | - | - |
$13,756
-
MMBtu
|
|
TOTAL RECOMMENDED | $23,623 | $4,500 |
$9,867
158,851
kWh
|
$13,756
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs