| Assessment Year | 1991 |
|---|---|
| Principal Product | ORGANIC CHEMICALS |
| NAICS |
n/a
|
| SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 350 |
| Plant Area |
n/a
|
| Annual Production | 70,000,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $646,567 | 19,321,220 |
kWh
|
$0.033 |
| Natural Gas | $1,048,836 | 311,928 |
MMBtu
|
$3.36 |
| Fuel Oil #2 | $61,749 | 16,642 |
MMBtu
|
$3.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $48,685 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $48,685 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $16,902 | $5,000 | - |
$16,902
-
MMBtu
|
- | |
| 02 | 2.2121: Increase amount of condensate returned | $20,762 | - | - |
$15,315
-
MMBtu
|
$5,447 | |
| 03 | 2.1321: Replace fossil fuel equipment with electrical equipment | $5,492 | - |
$(-12,156.0)
(-332,943)
kWh
|
$12,648
-
MMBtu
|
$5,000 | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,529 | - |
$6,020
212,192
kWh
|
$(-810.0)
-
MMBtu
|
$319 | |
| TOTAL RECOMMENDED | $48,685 | $5,000 |
$(-6,136.0)
(-120,751)
kWh
|
$44,055
-
MMBtu
|
$10,766 | ||
| TOTAL IMPLEMENTED | $48,685 | $5,000 |
$(-6,136.0)
(-120,751)
kWh
|
$44,055
-
MMBtu
|
$10,766 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs