| Assessment Year | 1984 |
|---|---|
| Principal Product | STAINLESS STEEL CASTINGS |
| NAICS |
n/a
|
| SIC | 3324: Steel Investment Foundries |
| Sales Range | $1 M to 5M |
| # of Employees | 40 |
| Plant Area |
n/a
|
| Annual Production | 750,000
lb
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,429 | 1,034,877 |
kWh
|
$0.083 |
| Natural Gas | $39,923 | 7,342 |
MMBtu
|
$5.44 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,605 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,093 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $8,182 | - |
$8,182
-
kWh
|
- | |
| 02 | 2.2511: Insulate bare equipment | $2,369 | $2,500 | - |
$2,369
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,542 | $387 |
$3,198
53,048
kWh
|
$(-656.0)
-
MMBtu
|
|
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $4,512 | $7,000 | - |
$4,512
-
MMBtu
|
|
| TOTAL RECOMMENDED | $17,605 | $9,887 |
$11,380
53,048
kWh
|
$6,225
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $13,093 | $2,887 |
$11,380
53,048
kWh
|
$1,713
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs