Assessment Year | 1984 |
---|---|
Principal Product | ELECTRICAL EQUIPMENT |
NAICS |
n/a
|
SIC | 3612: Power, Distribution, and Specialty Transformers |
Sales Range | $5 M to 10M |
# of Employees | 131 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $56,546 | 684,349 |
kWh
|
$0.083 |
Natural Gas | $19,871 | 3,562 |
MMBtu
|
$5.58 |
Fuel Oil #2 | $29,038 | 5,420 |
MMBtu
|
$5.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,509 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,700 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $6,700 | $3,000 |
$6,700
109,027
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $809 | $1,894 |
$965
11,723
kWh
|
$(-156.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $7,509 | $4,894 |
$7,665
120,750
kWh
|
$(-156.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,700 | $3,000 |
$6,700
109,027
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs