Assessment Year | 2021 |
---|---|
Principal Product | treated water |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $10 M to 50M |
# of Employees | 32 |
Plant Area |
150,000
ft2
|
Annual Production | 8,500,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $724,613 | 12,702,994 |
kWh
|
$0.057 |
Electricity Demand | $116,446 | 23,893 |
kW-mo/yr
|
$4.87 |
TOTAL YEARLY COSTS | $841,059 | |||
RECOMMENDED SAVINGS* | $166,471 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $166,471 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $161,890 | $279,811 |
$128,413
2,251,283
kWh
|
$32,400
-
kW-mo/yr
|
$1,077 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,488 | $5,859 |
$3,265
57,239
kWh
|
$200
-
kW-mo/yr
|
$23 | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $1,093 | $16,210 |
$789
13,829
kWh
|
$297
-
kW-mo/yr
|
$7 | |
TOTAL RECOMMENDED | $166,471 | $301,880 |
$132,467
2,322,351
kWh
|
$32,897
-
kW-mo/yr
|
$1,107 | ||
TOTAL IMPLEMENTED | $166,471 | $301,880 |
$132,467
2,322,351
kWh
|
$32,897
-
kW-mo/yr
|
$1,107 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs