| Assessment Year | 2020 |
|---|---|
| Principal Product | Lumber Trusses |
| NAICS | 321214: Truss Manufacturing |
| SIC | 2439: Structural Wood Members, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 111 |
| Plant Area |
76,000
ft2
|
| Annual Production | 200,000
pieces
|
| Production Hrs. Annual | 5,590
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $54,113 | 758,668 |
kWh
|
$0.071 | |
| Electricity Demand | $13,991 | 996 |
kW-mo/yr
|
$14.05 | |
| Electricity Fees | $5,575 | - |
|
- | |
| Natural Gas | $720 | 58 |
MMBtu
|
$12.52 | |
| Waste Disposal Costs | |||||
| Water Usage | $6,247 | 1,023 |
Tgal
|
$6.11 | |
| TOTAL YEARLY COSTS | $80,646 | ||||
| RECOMMENDED SAVINGS* | $4,831 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $3,241 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,808 | $1,868 |
$1,165
16,332
kWh
|
$506
-
kW-mo/yr
|
$137 | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,204 | $50 |
$764
10,709
kWh
|
$349
-
kW-mo/yr
|
$91 | - | |
| 03 | 2.7224: Reduce space conditioning during non-working hours | $928 | $221 |
$696
9,755
kWh
|
- | $57 |
$175
-
MMBtu
|
|
| 04 | 2.7221: Lower temperature during the winter season and vice-versa | $229 | $50 |
$189
2,653
kWh
|
- | $15 |
$25
-
MMBtu
|
|
| 05 | 2.7135: Install occupancy sensors | $546 | $546 |
$505
7,084
kWh
|
- | $41 | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $116 | $100 |
$73
1,025
kWh
|
$34
-
kW-mo/yr
|
$9 | - | |
| TOTAL RECOMMENDED | $4,831 | $2,835 |
$3,392
47,558
kWh
|
$889
-
kW-mo/yr
|
$350 |
$200
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,241 | $1,968 |
$2,118
29,694
kWh
|
$855
-
kW-mo/yr
|
$243 |
$25
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs