Assessment Year | 2014 |
---|---|
Principal Product | Heaters and Controls |
NAICS | 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing |
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
141,000
ft2
|
Annual Production | 3,600
pieces
|
Production Hrs. Annual | 4,125
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $238,202 | 3,583,200 |
kWh
|
$0.066 |
Electricity Demand | $93,378 | 7,921 |
kW-mo/yr
|
$11.79 |
Electricity Fees | $6,854 | - |
|
- |
Natural Gas | $36,782 | 3,748 |
MMBtu
|
$9.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,988 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,401 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,223 | $75 |
$827
12,521
kWh
|
$396
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,373 | $3,000 |
$1,848
28,018
kWh
|
$525
-
kW-mo/yr
|
|
03 | 2.7122: Disconnect ballasts | $214 | $70 |
$172
2,606
kWh
|
$42
-
kW-mo/yr
|
|
04 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $2,178 | $100 |
$1,002
15,182
kWh
|
$1,176
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $5,988 | $3,245 |
$3,849
58,327
kWh
|
$2,139
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $3,401 | $175 |
$1,829
27,703
kWh
|
$1,572
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs